Programmable Xenon Accelerated Aging Test Cabinet

Product Details
Customization: Available
Certification: Ce, RoHS, FCC, ISO, SGS Certificates
Humidity Range: 30%~98% Relative Humidity
Manufacturer/Factory, Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (26)
  • Programmable Xenon Accelerated Aging Test Cabinet
  • Programmable Xenon Accelerated Aging Test Cabinet
  • Programmable Xenon Accelerated Aging Test Cabinet
  • Programmable Xenon Accelerated Aging Test Cabinet
  • Programmable Xenon Accelerated Aging Test Cabinet
  • Programmable Xenon Accelerated Aging Test Cabinet
Find Similar Products

Basic Info.

Model NO.
ZH-XL-150
Temperature Range
0 Degree~80 Degree
Service
OEM / ODM / Non-Standard Available
Application
School, Hospital, Lab, Factory
Power Supply
AC220V/AC380V, Customized
Interior Sizes
W500×d500×h600mm
Wave Length Range
290-800nm
Black Panel Temp.
85 Degree
Light Source
Imported Full Spectrum Xenon Arc Lamp
Transport Package
Wooden Case
Specification
Customization available
Trademark
Sailham
Origin
Guangdong, China
HS Code
8479899990
Production Capacity
5000sets/Year

Product Description

Programmable Xenon Accelerated Aging Test Cabinet
Application
Programmable Xenon Accelerated Aging Test Cabinet is used to determine the color fastness, aging resistance of textiles, plastics, rubber products or materials by objecting to the simulated conditions of nature weather (daylight, rain, temperature and humidity, etc.). The chamber simulates both light and dark cycles and nature weather conditions by rack sprays and the long-arc-xenon lamp equipped.   
 
Features 
1. Light intensity set digitally, real-time monitoring, automatically adjust to meet the different standards required for testing the stability of light source (optional 420nm; 340nm or 300-400nm band monitoring)
2. Blackboard Thermometer (BPT), the Standard Blackboard Thermometer (BST), Irradiance detector and samples placed in the same position, a true reflection of the sample under test conditions, the data displayed as figures, charts, curves on the large color screen, no need to stop for observation.
3. Detection and wireless transmission using light energy conversion technologies for energy, not the other home power supply.
4. 10.4 inch color display, a variety of test monitoring modes (animation, digital, graphics) operate easily and clearly.
5. Sample holders can be timed independently to achieve different tests simultaneity in the same machine
6. Imported Atlas Rated 6500W/4500W long-arc-xenon- lamp, it truly simulates the daylight spectrum.
7. Professional water circulation system, reduce operating costs.
8. Industrial temperature control (cooling) system offers quickly and smoothly control
9. Ultrasonic humidifier, professional dehumidification system to ensure accurate and stable humidity conditions.
10. With self-circulation system and air filtration system, significantly reducing the environmental requirements.
11. Cooled by circulating water chillers / water cooling two options to choose from.
12. Quality assurance of 1000 hours continuous running.

Product Specifications
Model ZH-XL-150
Interior sizes  W500×D500×H600mm
Exterior sizes W1050×D1050×1750mm (or so)
Temp. range 0ºC~80ºC
Controller imported programmable 7inch touch screen
Material inner and outer 304# stainless steel
Sample holder Aluminum alloy frame base
Protection device residual-current circuit breaker (RCCB) to control the warning for loop overload, thermal protection and water shortage protection.
Temp. deflection ±2ºC  (without lighting)
Humid. range 30%~98%R.H
Humid. deflection ±2.5%R.H(Humid.≥75%R.H); ±3%R.H(Humid.≤75%R.H)(without lighting)
Light source imported full spectrum xenon arc lamp(average useful life 1600hrs)
Raining time 1~9999min (adjustable)
Raining period 1~240min, interval(cut)adjustable
lamp power Test period for Temp., irradiation, condensation, spray can be adjustable
Lamp 1.8KW
Wave length range 290-800nm
heating power (or so) 4.0KW
humidification (or so) 2.0KW
Light irradiance 1200w/m2
Distance between arc center and sample holder: 350~380mm
Revolving speed of sample holder ≥1r/min
Water spray period a. spray time: 0~99h59min (Continuing or adjustable)
b. stop time: 0~99h59min, (Continuing or adjustable) 
Lighting time Continuing programming control available
Black panel temp. 85±3ºC
Cooling method Mechanical wind cooling; Room temp. less than 26ºC is recommend, relative humid: ≤85%R.H; humid. and temp. tested after 2 hours under idle condition.
 

Product image
Programmable Xenon Accelerated Aging Test Cabinet

Trade show
Programmable Xenon Accelerated Aging Test Cabinet
Programmable Xenon Accelerated Aging Test Cabinet

Wooden case for export:
Programmable Xenon Accelerated Aging Test Cabinet

Certifications:
Programmable Xenon Accelerated Aging Test Cabinet
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now